![]() View Full-Size Image |
£825.00
(Excluding VAT @ 17.5%)
|
Powerful, yet small and lightweight, the Castle GA156 noise dosemeter combines the latest technological advances with a realistic price tag. With it’s clear and easy to read 8 character alpha numeric display, softtouch keypad, electronic security lock and instant calibration facility, the GA156 is sure to prove invaluable in a wide range of occupational health applications.
Downloading to a personal computer via Castle’s dBdataPRO software for Windows will lead you into a whole new area of power and flexibility.
Mobility of instrumentation is essential for effective noise measurement. As the name indicates, the Castle ‘Pocket Range’ packs all the necessary features into pocket sized proportions
All measured values are held within the memory of the GA156 for subsequent output. The results can be viewed on the instruments own display, printed out or downloaded to a PC.
A particularly important feature in a dosemeter is security. The GA156 has the ability to lock the keypad with just two keystrokes. From this state, all of the functions will be inoperable. To unlock the instrument, a code is required which is supplied with the unit.
The measured noise is computed and stored as a series of Lep’d and DOSE values in pre-chosen time intervals. Using the five memory stores which can be selected from the menu, data can be logged for five different employees or five different days. The GA156 will store 1 minute values or 10 minute values to give more or less detail as required.
Each GA156 is supplied in it’s own plastic case complete with a handbook, windshield, calibration screwdriver and pen. A full range of kits are also available with calibrators, printers and software.
Tender Specifications
To measure dose, projected dose, DOHR (Dose per Hour) Lepd, projected Lepd, Pa2H 115dB RMS and 200Pa peak Flags with user selectable Criterion and Factory selectable Exchange rate.
To log results into 5 memory locations which can then be downloaded via RS232C direct to a printer to provide alpha-graphic reports or into a Personal Computer using relevant software. 8 character alpha -numeric LCD.
To act as a dedicated personal sound exposure meter
To fit into small shirt or jacket pocket.
Lockable Key pad.
To be constructed of tough crack resistance plastic.
Single battery operation for approximately 15 hours.
To have strong clip for attaching to a belt or shirt pocket
GA156 Specification
Data-logging Personal Sound Exposure Meter
Measuring range: 75 - 135 dB (85dB Criterion), 80 - 140 dB (90dB Criterion)
Dynamic range: 60 dB
Detector Characteristics: RMS and Peak
Frequency Weighting: ‘A’ Weighted in Accordance with BSEN60651
Time Weighting: ‘Slow’ in Accordance with BSEN60651
Exchange rate: 3dB or 5dB Doubling
Criterion Level (Key pad selectable): 90dBA for 8 hours = 100% DOSE or 85dBA for 8 hours = 100% DOSE
Threshold Level: 80dBA or 75dBA
RMS Detector: Normally set at 115dBA rms
Peak flag: 140dB 200Pa Linear frequency weighted
Unless otherwise specified at the time of order, the GA156 will be delivered with the following default settings: 3dB exchange rate, 90dB criterion, 80dBA threshold,115dBA RMS trigger and 200 Pa peak flag.
Display: Digital 1 x 8 alphanumeric, digit size 7mm x 5mm Liquid Crystal Display
Memory: 5 Employee records storing 1 - minute values - 20 hours, 10 - minute values - 9 days (power dependant)
Microphone/Preamp: Pre-polarised ½" condenser microphone, Cable length 0.8m
Calibration: In ‘CAL’ mode, instrument displays 1 second Leq’s over limited range. Instrument is then acoustically calibrated using GA601 or GA607 at 94dB or 104dB at 1KHz Potentiometer adjusted. Reference Frequency: 1KHz. Reference SPL: 94dB
Batteries: Type: IEC No. 6LR61. Life: for Duracell MN1604 - ~15 hours continuous
Temperature: Operating range: -10 to + 50°C, Storage without batteries: -20 to + 70°C
Humidity: Effect: < 0.5dB from 30% to 90% RH
Vibration: A 40Hz 1m/s vibrating force produces no noticable effect
Magnetic Field: 80A/m (1Oersted) at 50Hz produces < 0.5dB error
Standards: Compliance with BS6402 (Dosemeters) and Designed to meet the requirement of the EMC regulations
Construction: Small, lightweight case of fibre-filled, ABS plastic
Operation: Microprocessor based operation, tactile keypad operation, state of the art electronic design
Display parameters include :-
Projected Lep’d 75dB to 135dB
Pa2Hrs (Dose % x 0.032)
Sound Pressure Level for calibration to 0.1dB resolution
Lpeak (Maximum linear peak hold)
Dose count 1% to 9999% with Variable exchange rate of 3dB/5dB and criterion level 85dB/90dB for Dose calculations
Projected Dose 1% to 9999%
‘A’ frequency weighting
‘Slow’ time weighting
Elapsed time (Running time hrs, mins, secs, 1%)
Overload indication (Flashing alternate display)
Battery condition indication
Low battery (Flashing alternate display)
115 dBA Flag and Time of first occurrence (factory selectable to other levels if required)
| Sound Meters |
| Calibrators |
| Noise Activated Warning |
| Audiometers |
| Vibration Meters |
| Tool Timers |
| Accessories |
| Gas Detection |
| Light Meters |
| Air Sampling |
| Temperature and Humidity |
| Noise Meter Kits |
| Precision Noise Kits |
| Vibration Kits |
| Training Home |
| Training Courses |
| Seminars |
| Location Details |
| Calibration |
| Rental |
| Consultancy |
| Media |
| Sitemap |
| Overseas Distributors |
| Lost Password? | |
| No account yet? Register | |
|
|
Noise and Vibration
Hull - 11 Dec 2008
Environmental Noise
Cardiff - 23 April 2009
Audiometry
Peterboro - 29 Jan 2009
COSHH & Air Sampling
Harrogate - 28 May 2009